搜索

YJV22-3*6 power cable

The performance of XLPE insulated (flame retardant) power cable meets the national standard GB / t12706.1-2008, and the equivalent adopts iec60502-2004. The flame retardant meets the national standard GB / t19666-2005.
Keyword:
YJV22-3*6 power cable
Service: +86-13001249999
YJV22-3*6 power cable
Introduction

Purpose description

XLPE insulated power cable not only has excellent electrical performance, mechanical performance, heat aging resistance, environmental stress resistance and chemical corrosion resistance, but also has the advantages of simple structure, convenient use, not limited by laying drop, high long-term working temperature (90 degrees) and large transmission capacity. XLPE insulated power cable products have flame retardant Non flame retardant full series XLPE insulated power cable.

Executive standard

The performance of XLPE insulated (flame retardant) power cable meets the national standard GB / t12706.1-2008, and the equivalent adopts iec60502-2004. The flame retardant meets the national standard GB / t19666-2005.

Scope of application

★ System: This product is suitable for transmitting electric energy in power lines with AC 50Hz and rated voltage of 0.6/1kv (maximum system voltage of 1.2KV).
★ Occasion: it is laid in indoor, cable trench, pipeline, directly buried and can not bear external mechanical force in metallurgy, electric power, construction and other industries.

Usage characteristics

★ Rated voltage: the rated voltage of power frequency AC is 0.6/1kv, and the maximum voltage of AC system shall not exceed 1.2KV.
★ Working temperature: the maximum allowable working temperature of cable conductor for a long time is 90 ℃. In case of short circuit, the maximum temperature of cable conductor is 250 ℃, and the duration shall not exceed 5S.
★ Ambient temperature: the minimum ambient temperature for cable operation is - 10 ℃.
★ Laying temperature: during installation and laying, the temperature shall not be lower than 0 ℃.
★ Bending radius: the minimum bending is recommended. The bending radius of single core cable shall not exceed 20d and that of multi-core cable shall not exceed 15d.

Model and name

Model Name Use occasion
Copper core Aluminum core
YJV
ZR-YJV
YJLV
ZR-YJLV
XLPE insulated PVC sheathed (flame retardant) power cable When it is laid in indoor and outdoor tunnels, cable trenches, or in loose soil, and can withstand certain laying traction, but can not withstand external mechanical force, single core cables are not allowed to be laid in magnetic pipes
WDZ-YJY WDZ-YJLY XLPE insulated low smoke halogen-free sheathed power cable
YJV22
ZR-YJV22
YJLV22
ZR-YJLV22
XLPE insulated steel tape armored PVC sheathed (flame retardant) power cable It is laid outdoors and buried. It can bear external mechanical force, but can not bear large tensile force
YJV62
ZR-YJV62
YJLV62
ZR-YJLV62
XLPE insulated non-magnetic metal tape armored PVC sheathed (flame retardant) power cable
WDZ-YJY23 WDZ-YJLY23 XLPE insulated steel tape armored low smoke halogen-free sheathed power cable
YJV32
ZR-YJV32
YJLV32
ZR-YJLV32
XLPE insulated fine steel wire armored PVC sheathed (flame retardant) power cable It can bear external mechanical force and considerable tensile force when laid in shaft water or high drop area
YJV72
ZR-YJV72
YJLV72
ZR-YJLV72
XLPE insulated non-magnetic metal wire armored PVC sheathed (flame retardant) power cable
WDZ-YJY33 WDZ-YJLY33 XLPE insulated fine steel wire armored low smoke halogen-free sheathed power cable
YJV42
ZR-YJV42
YJLV42
ZR-YJLV42
Cross linked polyethylene insulated thick steel wire armored PVC sheathed (flame retardant) power cable Laid in shaft, seabed or high drop area, the cable can bear large positive pressure and tension
WDZ-YJY43 WDZ-YJLY43 XLPE insulated thick steel wire armored low smoke halogen-free sheathed power cable

Structural diagram

Structural diagram

There is currently no content to display
Please add data record on website background.
INQUIRY
Our staff will contact you within 24 hours (working days). If you need other services, please call the service hotline: +86-317-2863988
全部评论
已有0条评论
There is currently no content to display
Please add data record on website background.

BOYI WIRE & CABLE

SERVICE: +86-13001249999
TEL: +86-317-2863988
FAX: +86-317-2863688
ADD: Yincun Industrial Zone, Renqiu City, Hebei Province

COPYRIGHT © 2021 BOYI WIRE & CABLE
gotop